5V-24V Motor Forward/Reverse Controller with Delay Timer, 8x5cm

CZK309.00
+ CZK101.99 Shipping

5V-24V Motor Forward/Reverse Controller with Delay Timer, 8x5cm

  • Brand: Unbranded
Sold by:

5V-24V Motor Forward/Reverse Controller with Delay Timer, 8x5cm

  • Brand: Unbranded
RRP: CZK469.00
Price: CZK309.00
You save: CZK160.00 (34%)
Sold by:
CZK309.00
+ CZK101.99 Shipping

In stock

We accept the following payment methods

Description

5V - 24V Motor Forward / Reverse Controller Timing Delay Time Cycles Relay Features: Dual power supply (two power supplies cannot be powered at the same time): Power supply 1, DC 6.5-25V; Power supply 2, DC 5V    Working current: (Normal Mode) standby current 41mA, working current 83mA; (Energy-Saving mode) Standby current 7mA, working current 44mA.    There are three input control port: forward control(FWD), reverse control(REV), and stop control(STOP).    Two input trigger modes, Low-Pulse trigger mode, Low-Level trigger mode    Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes.    Cycle times: no cycle, 2-99 cycles, always cycle.    Three indicators: forward indicator(F LED), reverse indicator(R LED), stop indicator(S LED).    Relay load current, recommended less than 5A. This is a multi-function DC/AC motor forward and reverse controller with multiple control modes. Many control functions can be derived through reasonable settings. Port:       DC 5.5MM female : Power supply 1, DC 5V power supply.  VIN: Power 2 positive, DC 6.5-25V power supply  GND: Power supply 2 negative  FWD: Forward input control (partial Function-Mode is invalid)  REV: Reverse input control (partial Function-Mode is invalid)  STOP : Stop input control (partial Function-Mode is invalid)  M+: Motor positive   M-: Motor negative  P+: Positive terminal for motor power supply P-: negative terminal for motor power supply   Specification: Power supply: DC 6.5-25V, DC 5V Working current: 83mA Standby current: 41mA Relay load current: <5A Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes Size: 8*5cm/3.2*2in Weight: Approx. 51g/1.8oz Trigger mode:  1 low pulse trigger (falling edge trigger) 2 low level trigger (rising edge trigger)     Timer:  T1: Forward timer T2: Reverse timer T3: Stop timer Time unit : 0.1 second, 1 second, 1 minute     Relay action:  Motor forward : Relay 1 is ON, relay 2 is OFF, and the F LED indicator is flashing. Motor reverse : Relay 1 is OFF, relay 2 is ON, and the R LED indicator is flashing.. Motor stop   : Relay 1 is OFF, relay 2 is OFF, and the S LED indicator is flashing.     Factory settings:  Press the "++" and "--" buttons simultaneously for 5 seconds.     Energy-saving mode:  Press and hold the "OK" button for 5 seconds to enter the "Energy-saving mode". Press and hold the "OK" button again for 5 seconds to exit the "Energy-saving mode". Energy saving mode just turns off the digital tube and LED indicator, and other functions are normal.   Function mode:  F-01 After power-on, the motor is forward T1 time; then the motor stops T3 time; then the motor reverse T2 time; so it is repeated Nx times. When the STOP port is triggered, the motor stops working immediately. (FWD, REV port is invalid)    F-02 This function is a F-01 variant. F-01 is run directly after power-on, but F-02 needs to trigger FWD or REV port to run.    F-11(Trigger  reversible 1) Trigger the FWD port, the motor is forward T1 time, and automatically stops (in order to protect the motor, during the delay period, trigger the REV port to stop T3 time and then reverse T2 time, trigger FWD port to re-time T1). Trigger the REV port, the motor is reverse T2 time, and automatically stops (in order to protect the motor, during the delay period, the FWD port is triggered to stop the T3 time and then the T1 time is forward, and the REV port is re-timed T2). When the STOP port is triggered, the motor stops immediately, regardless of whether the motor is forward or reverse.     F-12(Trigger  reversible 2) Trigger the FWD port, the motor is forward T1 time and stops automatically (during the delay period, except for triggering STOP port, the other ports are invalid). Trigger the REV port, the motor is reverses T2 time, and automatically stops (during the delay period, except for triggering STOP port, the other ports are invalid). When the STOP port is trigger, the motor stops immediately, regardless of whether the motor is forward or reverse.     F-21 When the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops. When the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops. In this mode, the FWD and REV ports cannot be connected low level at the same tim
  • Fruugo ID: 415389671-876936588
  • EAN: 8461339294249

Delivery & Returns

Dispatched within 24 hours

  • STANDARD: CZK101.99 - Delivery by Tue 21 October 2025

Shipping from China.

We do our best to ensure that the products that you order are delivered to you in full and according to your specifications. However, should you receive an incomplete order, or items different from the ones you ordered, or there is some other reason why you are not satisfied with the order, you may return the order, or any products included in the order, and receive a full refund for the items. View full return policy

Product Compliance Details

Please see the compliance information specific to this product outlined below.

The following information is provided by the independent third-party retailer selling this product.

Manufacturer
The following information outlines the contact details for the manufacturer of the relevant product sold on Fruugo.

  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
  • Room201,AreaB,No.280,Zhongshan Avenue East
  • Huangpu
  • Guangzhou
  • Guangdong
  • China
  • 518000
  • firzen.pan@gmail.com
  • +8619128656319

Responsible Person in the EU
The following information outlines the contact information for the responsible person in the EU. The responsible person is the designated economic operator based in the EU who is responsible for the compliance obligations relating to the relevant product sold into the European Union.

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM.1.PLANTA 1,DERECHA.OFICINA3.Fuenlabrada.
  • Madrid
  • Spain
  • 28947
  • successservice2@hotmail.com
  • +34910602659