Popis
Product function introduction:
The one-way temperature controller can set as "refrigerating" or "heating", using 10K general NTC thermistor to control temperature, control the one-way relay (NO, NC) output. The temperature range controlled is -45-110. It is used extensively in various refrigerating and heating situations.
Under refrigerating mode, the output opens when the temperature is above (temperature control value + backlash), and stops when temperature is the at temperature control value.
Under heating mode, the output opens when the temperature is below (temperature control value - backlash), and stops when temperature is the at temperature control value.
The temperature control value and backlash are adjustable. Correction function for temperature deviation is also available.
DIN rail-type installation is adopted which is easy and fast for installing.
The advanced design of isolating power supply is adopted, which can ensure the controller work steadily, reliably, and continuously when the power supply changes between 100V and 240VADC.
Main Features:
One-way 10K NTC temperature sensor input
One-way NO & NC output
Temperature display
Shifting between the refrigerating and heating modes
Delay protection of compressor
Correction of measured temperature deviation
Power-down memory protection function
Panel introduction
1.The indicator light is lit when the relay NO pulls-in.
2. LED display window: temperature is displayed during work (T temperature = T temperature measured + T deviation)
3. (erected triangle)is parameter plus adjust key under set state; Under work state, press it for long to check the temperature control value set.
4. (SET) set key, press it to start the parameter set state and press one by one to shift to display each parameter.
5. (Inverted triangle)is parameter minus adjust key under set state.
6. If no action is conducted in 3 min after adjusting, the interface will return to the main interface automatically, displaying current temperature.
Detailed introduction of the control function:
Short name of control function
Control function introduction
Other introduction
Temperature measuring correction
Displayed T temperature = T measured temperature + T deviation
Temperature control output
1. Under H mode, when T temperatureT temperature control, the relay NO is off, output stops; when T temperature is(T temperature - T backlash), the relay NO pulls-in again, heating output starts;
2. Under L mode, when the T temperatureT temperature control, the relay NO is off, output stops; when T temperature is(T temperature + T backlash), the relay NO pulls-in again, refrigerating output starts;
The time for relay output open-- close or close-- open shall not be shorter than the Pt set value.
Operation guide:
Press(SET)to start setting parameter, press one by one to shift to display each parameter; (erected triangle)(Inverted triangle )is used to adjust the value. After setting, press continuously the(SET) key until the main interface is get.
Times pressing(SET)
Display
Parameter explanation
Function introduction and short name
Parameter set range
Factory setting
1
-H-
HL
Selection of heating/refrigerating (H is heating mode, L is refrigerating mode)
H/L
H
2
-1-
Parameter 1
3
Upper limit of temperature control
Temperature control value when relay NO output stops
-45-110
25
4
-2-
Parameter 2
5
d
Temperature control backlash value
1-30
2
6
-3-
Parameter 3
7
Delay time, controlling the minimum delay time of the relay output open-- close or close-- open (the delay time should be set as 2-3 min for refrigerating compressor for protection)
0-300 S
1S
8
-4-
Parameter 4
9
SC
Correction of measured temperature deviation
-25-25
0
Technical Parameter:
External dimension (mm):L 93 x W 55 x H 44
Installation mode:The controller installation could be standard DIN rail installation or fixed installation
Power supply and consumed power at work:ADC(100-240)V,2W
Application environment:-10-50
Display mode:Three LED digit display
Key:Press-type membrane key
Input:One-way (10K)NTC thermistor temperature sensor output, measuring range of -50-120
Output:
1. One-way relay NO, NC refrigerating/heating output
2. The current capacity of the output contact is 5 ampere of restrictive load and 1 ampere of inductive load. It can control the 1000W electrical heating or electrical motor or water pump of 200W. A.C. contactor is needed to enlarge the capacity for more load.
Measurement range:-50-120
Set range:
Minimum limit: -45-controlled temperature
Maximum limit: controlled temperature-110
Control range:-45-110
Other parameter:
1. The temperature sensing line could be connected with general wire for 100 meters
2. Set the parameter to
-
Fruugo ID:
296740437-663852612
-
EAN:
8154069143948
Informace o bezpečnosti produktu
Přečtěte si prosím níže uvedené informace o bezpečnosti produktu specifické pro tento produkt
Následující informace poskytuje nezávislá třetí strana prodejce tohoto produktu.
Bezpečnostní štítky produktu
bezpečnostní upozornění:
Not suitable for children under 36 months old
Doručení a vrácení
Odesláno do 2 dnů
-
EXPRESS:
116,49 Kč
- Doručení mezi pá 17 října 2025–pá 24 října 2025
- Nejlevnější
- Nejrychlejší
-
STANDARD:
143,49 Kč
- Doručení mezi út 28 října 2025–st 05 listopadu 2025
Doprava od Čína.
Děláme, co můžeme, aby k vám produkty, které si objednáte, dorazily kompletní a splňovaly vaše specifikace. Pokud však objednávka dorazí nekompletní, produkty jsou rozdílné od těch, které jste si objednali, nebo existuje jiný důvod k nespokojenosti s objednávkou, můžete objednávku nebo jakékoliv v ní obsažené produkty vrátit a obdržet za ně plnou náhradu. Zobrazit kompletní zásady vrácení