Dual Channel Relay Module with LCD Display for Temperature and Humidity Control, 10A Thermostat Sensor Rail System

999,00 Kč
+ 288,49 Kč Doprava

Dual Channel Relay Module with LCD Display for Temperature and Humidity Control, 10A Thermostat Sensor Rail System

  • Značka: Unbranded
Prodal(a):

Dual Channel Relay Module with LCD Display for Temperature and Humidity Control, 10A Thermostat Sensor Rail System

  • Značka: Unbranded

999,00 Kč

Uložit 600,00 Kč (37%)

Doporučená cena

1 599,00 Kč
Skladem
+ 288,49 Kč Doprava
Prodal(a):

999,00 Kč

Uložit 600,00 Kč (37%)

Doporučená cena

1 599,00 Kč
Skladem
+ 288,49 Kč Doprava

Přijímáme následující platební metody

Popis

Dual Channel Relay Module with LCD Display for Temperature and Humidity Control, 10A Thermostat Sensor Rail System

The product features temperature and humidity control functions. Temperature functions: 1. Automatic mode detection: The system automatically identifies the operating mode based on start and stop temperatures. If start temperature is higher than stop temperature, it enters cooling mode (C). If start temperature is lower than stop temperature, it enters heating mode (H). 2. Cooling mode: When the detected temperature rises above the start temperature, the relay activates, the red indicator light turns on, and the cooling equipment starts. When the temperature drops to the stop temperature, the relay turns off, the red light turns off, and the cooling equipment stops. 3. Heating mode: When the detected temperature falls below the start temperature, the relay activates, the red indicator light turns on, and the heating equipment starts. When the temperature reaches the stop temperature, the relay turns off, the red light turns off, and the heating equipment stops. 4. Temperature correction (OFE: -10.0 to 10.0): To correct measurement deviations after prolonged use, the actual temperature is calculated as: measured temperature + correction value. How to set start/stop temperature: - From the running interface, press and hold the "TM+" button for more than 3 seconds to enter the start temperature setting. Adjust the value using the TM+ and TM- buttons. After setting, wait 6 seconds for the system to save and exit automatically. - From the running interface, press and hold the "TM-" button for more than 3 seconds to enter the stop temperature setting. Adjust the value using the TM+ and TM- buttons. After setting, wait 6 seconds for the system to save and exit automatically. Humidity functions: 1. Automatic mode detection: The system automatically identifies the operating mode based on start and stop humidity levels. If start humidity is higher than stop humidity, it enters dehumidification mode (d). If start humidity is lower than stop humidity, it enters humidification mode (E). 2. Dehumidification mode: When the detected humidity exceeds the start humidity, the relay activates, the green indicator light turns on, and the dehumidification equipment starts. When the humidity drops to the stop humidity, the relay turns off, the green light turns off, and the equipment stops. 3. Humidification mode: When the detected humidity falls below the start humidity, the relay activates, the green indicator light turns on, and the humidification equipment starts. When the humidity reaches the stop humidity, the relay turns off, the green light turns off, and the equipment stops. 4. Humidity correction (RH: -10.0 to 10.0): To correct measurement deviations after prolonged use, the actual humidity is calculated as: measured humidity + correction value. How to set start/stop humidity: - From the running interface, press and hold the "RH+" button for more than 3 seconds to enter the start humidity setting. Adjust the value using the RH+ and RH- buttons. After setting, wait 6 seconds for the system to save and exit automatically. - From the running interface, press and hold the "RH-" button for more than 3 seconds to enter the stop humidity setting. Adjust the value using the RH+ and RH- buttons. After setting, wait 6 seconds for the system to save and exit automatically.
  • Fruugo ID: 399229885-850166315
  • EAN: 1243206498571

Informace o bezpečnosti produktu

Přečtěte si prosím níže uvedené informace o bezpečnosti produktu specifické pro tento produkt

Následující informace poskytuje nezávislá třetí strana prodejce tohoto produktu.

Bezpečnostní štítky produktu

CE Mark
bezpečnostní upozornění: Check the product before use to ensure that the product is not damaged.
Číslo dílu výrobce: RK43531
Číslo modelu: RU43531
sériové číslo: LK43531
Číslo šarže: GL43531

Doručení a vrácení

Odesláno do 24 hodin

  • STANDARD: 288,49 Kč - Doručení mezi st 17 prosince 2025–čt 25 prosince 2025

Doprava od Čína.

Děláme, co můžeme, aby k vám produkty, které si objednáte, dorazily kompletní a splňovaly vaše specifikace. Pokud však objednávka dorazí nekompletní, produkty jsou rozdílné od těch, které jste si objednali, nebo existuje jiný důvod k nespokojenosti s objednávkou, můžete objednávku nebo jakékoliv v ní obsažené produkty vrátit a obdržet za ně plnou náhradu. Zobrazit kompletní zásady vrácení

Podrobnosti o shodě produktu

Přečtěte si prosím níže uvedené informace o shodě specifické pro tento produkt.

Následující informace poskytuje nezávislá třetí strana prodejce tohoto produktu.

Výrobce:
V následujících informacích jsou uvedeny kontaktní údaje na výrobce příslušného výrobku prodávaného na Fruugo.

  • Chen Ge
  • Shanghai Ganlan Network Technology Co., Ltd.
  • No. 139, Rongmei Road, Building 1,Songjiang District,Shanghai City
  • Shanghai
  • CN
  • 201601
  • qizao88361@163.com
  • 13413952153

Odpovědná osoba v EU:
V následujících informacích jsou uvedeny kontaktní údaje na odpovědnou osobu v EU. Odpovědná osoba je určený ekonomický subjekt působící v rámci EU, který je odpovědný za dodržování požadavků stanovených pro příslušný výrobek prodávaný do Evropské unie.

  • Van Lavazza
  • Y & H S.R.L.
  • Via Gravina 21 MT matera,Trani,Puglia
  • Trani
  • Italy
  • 75100
  • itlyhsrl@gmail.com
  • 0039 3917722149