Interrupteur de débit d'eau/à palette 1/2, connexion filetée, contacts SPDT rouges (type partiellement en acier inoxydable)

824,00 Kč
doprava ZDARMA

Interrupteur de débit d'eau/à palette 1/2, connexion filetée, contacts SPDT rouges (type partiellement en acier inoxydable)

  • Značka: Unbranded
Prodal(a):

Interrupteur de débit d'eau/à palette 1/2, connexion filetée, contacts SPDT rouges (type partiellement en acier inoxydable)

  • Značka: Unbranded
Doporučená prodejní cena: 1 099,00 Kč
Cena: 824,00 Kč
Ušetříte: 275,00 Kč (25%)
Prodal(a):
824,00 Kč
doprava ZDARMA

Skladem

Přijímáme následující platební metody

Popis

Features: 100% brand new and high quality The product is used to measure the dynamic state of the liquid flowing through the pipeline, such as: water, ethylene, ethylene glycol and other liquids that have no corrosive effect on copper Application: water treatment system, central air conditioning, water cooling unit, fire protection system and other fields. Adopts premium material, with strong temperature adaptability of 0℃~ 120℃, and can withstand high pressure of 1.0Mpa. The flow control value is adjustable and the action repetition point is stable. Specification: Material:brass and stainless steel(body), stainless steel( Leaf blade), plastic (shell) Interface dimensions: 1/2"(HFS-15) Control mode: blade type Max. working pressure: 1.0Mpa Ambient temperature: 0C~60℃ Liquid temperature: -10~100℃(non-freezing) Micro switch: single pole double throw (SPDT) Contact life: 100, 000 cycles Electrical parameters of micro - switch: 220VAC, 15A Weight: Approx.407g/14.4oz Package list: 1 x flow switch 1 x Chinese and English operation manual 3 x paddle Installation and adjustment: 1. Open the flow switch housing; 2. The switch has been set at the minimum flow value when leaving the factory. Increase the flow setting value and turn the adjusting screw counterclockwise; 3. Press the target to check whether the micro switch can work normally. Excessive clockwise rotation of the adjustment screw may lead to the failure of the flow switch; 4. After the installation, please press the lever of flow switch several times to check. Once it is found that there is no "click" sound when the lever is restored, rotate counterclockwise Adjust the screws until there is a "click" sound; 5. The adjustment screw of lacquer seal is only for factory to adjust the state of flow switch. Please do not change or adjust it 6. Observe three working cycles, make sure that the switch and the system connected with it are in normal operation, and cover the switch shell in time. Matters needing attention: 1. Please check the flow switch carefully before installation. The package should be complete and the appearance should be free from damage and deformation. If you have any questions, please contact the manufacturer: 2. The flow switch can be installed in the horizontal pipe or the vertical pipe with the upward direction of liquid flow, but it cannot be installed in the pipe with the downward direction of liquid flow. Gravity should be considered when installing in piping above the flow direction of the fluid 3. The flow switch must be installed on the straight pipe of the section, both sides of which are short of the straight stroke of 5 letter pipe diameter. At the same time, it should be noted that the direction of liquid flow in the pipe must be consistent with the direction of arrow on the switch shell. 4. The HFS flow switch shall not be used in pipelines where the liquid temperature drops below the freezing point of the liquid. 5. The HFS flow switch cannot be hit by water. If there is a quick closing valve in the downstream of the flow switch, the throttle must be used. 6. When installing wiring, please pay attention to the following matters: * it is absolutely forbidden to impact the wrench on the switch bottom plate, resulting in deformation failure of the flow switch; * to avoid electric shock and damage to the equipment, cut off the power supply when wiring or debugging; * when wiring, it is absolutely forbidden to adjust any screws other than micro switch terminals and grounding screws. It should be noted that the micro switch wiring cannot be used If the force is too strong, it will easily cause the position displacement of the micro switch itself and lead to the failure of the flow switch. * special grounding screws must be used for wiring, and installation screws cannot be removed at will, otherwise the controller will be deformed and invalid; * the blade of the flow switch cannot contact with the inner wall of the pipe and other throttles in the pipe, otherwise the switch cannot be reset normally.
  • Fruugo ID: 420712130-886410436
  • EAN: 7011292101507

Informace o bezpečnosti produktu

Přečtěte si prosím níže uvedené informace o bezpečnosti produktu specifické pro tento produkt

Následující informace poskytuje nezávislá třetí strana prodejce tohoto produktu.

Bezpečnostní štítky produktu

CE Mark
bezpečnostní upozornění: Warning: Please read the product instructions carefully before use to ensure correct use.
sériové číslo: 7011292101507

Doručení a vrácení

Odesláno do 2 dnů

  • STANDARD: ZDARMA - Doručení mezi st 15 října 2025–st 22 října 2025 - ZDARMA

Doprava od Čína.

Děláme, co můžeme, aby k vám produkty, které si objednáte, dorazily kompletní a splňovaly vaše specifikace. Pokud však objednávka dorazí nekompletní, produkty jsou rozdílné od těch, které jste si objednali, nebo existuje jiný důvod k nespokojenosti s objednávkou, můžete objednávku nebo jakékoliv v ní obsažené produkty vrátit a obdržet za ně plnou náhradu. Zobrazit kompletní zásady vrácení

Podrobnosti o shodě produktu

Přečtěte si prosím níže uvedené informace o shodě specifické pro tento produkt.

Následující informace poskytuje nezávislá třetí strana prodejce tohoto produktu.

Výrobce:
V následujících informacích jsou uvedeny kontaktní údaje na výrobce příslušného výrobku prodávaného na Fruugo.

  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • No. 1-1, Door 57
  • Shihua Village
  • Qingshan District
  • Wuhan
  • CN
  • 430000
  • goldxinks@163.com
  • 0086 17786498762
  • https://shop01473o1711614.1688.com/page/creditdetail.htm?spm=a261y.7663282.shopNavigation.1.6310755czE9SFQ

Odpovědná osoba v EU:
V následujících informacích jsou uvedeny kontaktní údaje na odpovědnou osobu v EU. Odpovědná osoba je určený ekonomický subjekt působící v rámci EU, který je odpovědný za dodržování požadavků stanovených pro příslušný výrobek prodávaný do Evropské unie.

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795